<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN">

<!--Converted with LaTeX2HTML 2008 (1.71)
original version by:  Nikos Drakos, CBLU, University of Leeds
* revised and updated by:  Marcus Hennecke, Ross Moore, Herb Swan
* with significant contributions from:
  Jens Lippmann, Marek Rouchal, Martin Wilck and others -->
<HTML>
<HEAD>
<TITLE>clamav-milter</TITLE>
<META NAME="description" CONTENT="clamav-milter">
<META NAME="keywords" CONTENT="clamdoc">
<META NAME="resource-type" CONTENT="document">
<META NAME="distribution" CONTENT="global">

<META NAME="Generator" CONTENT="LaTeX2HTML v2008">
<META HTTP-EQUIV="Content-Style-Type" CONTENT="text/css">

<LINK REL="STYLESHEET" HREF="clamdoc.css">

<LINK REL="next" HREF="node23.html">
<LINK REL="previous" HREF="node20.html">
<LINK REL="up" HREF="node19.html">
<LINK REL="next" HREF="node23.html">
</HEAD>

<BODY >

<DIV CLASS="navigation"><!--Navigation Panel-->
<A NAME="tex2html399"
  HREF="node23.html">
<IMG WIDTH="37" HEIGHT="24" ALIGN="BOTTOM" BORDER="0" ALT="next" SRC="next.png"></A> 
<A NAME="tex2html395"
  HREF="node19.html">
<IMG WIDTH="26" HEIGHT="24" ALIGN="BOTTOM" BORDER="0" ALT="up" SRC="up.png"></A> 
<A NAME="tex2html389"
  HREF="node21.html">
<IMG WIDTH="63" HEIGHT="24" ALIGN="BOTTOM" BORDER="0" ALT="previous" SRC="prev.png"></A> 
<A NAME="tex2html397"
  HREF="node1.html">
<IMG WIDTH="65" HEIGHT="24" ALIGN="BOTTOM" BORDER="0" ALT="contents" SRC="contents.png"></A>  
<BR>
<B> Next:</B> <A NAME="tex2html400"
  HREF="node23.html">Testing</A>
<B> Up:</B> <A NAME="tex2html396"
  HREF="node19.html">Configuration</A>
<B> Previous:</B> <A NAME="tex2html390"
  HREF="node21.html">On-access scanning</A>
 &nbsp; <B>  <A NAME="tex2html398"
  HREF="node1.html">Contents</A></B> 
<BR>
<BR></DIV>
<!--End of Navigation Panel-->

<H2><A NAME="SECTION00052000000000000000"></A><A NAME="sec:clamavmilter"></A>
<BR>
clamav-milter
</H2>
    ClamAV <SPAN CLASS="MATH"><IMG
 WIDTH="58" HEIGHT="35" ALIGN="MIDDLE" BORDER="0"
 SRC="img4.png"
 ALT="$\ge0.95$"></SPAN> includes a new, redesigned clamav-milter. The most notable
    difference is that the internal mode has been dropped and now a working
    clamd companion is required. The second important difference is that now
    the milter has got its own configuration and log files. 
    
<BR>
<BR>
To compile ClamAV with the clamav-milter just run <code>./configure</code>
    <code>--enable-milter</code> and make as usual. In order to use the 
    '-enable-milter' option with 'configure', your system MUST have the milter 
    library installed.  If you use the '-enable-milter' option without the 
    library being installed, you will most likely see output like this during 
    'configure':
    <PRE>
        checking for libiconv_open in -liconv... no
        checking for iconv... yes
        checking whether in_port_t is defined... yes
        checking for in_addr_t definition... yes
        checking for mi_stop in -lmilter... no
        checking for library containing strlcpy... no
        checking for mi_stop in -lmilter... no
        configure: error: Cannot find libmilter
</PRE>
    At which point the 'configure' script will stop processing.
    
<BR>
<BR>
Please consult your MTA's manual on how to connect ClamAV with the milter.